Discard sensor temperature alert status flags (#46)

Per [specification the broadcast message](https://github.com/OpenWonderLabs/SwitchBotAPI-BLE/blob/latest/devicetypes/meter.md#meter-broadcast-message-format) byte 3 includes the device temperature and humidity alert status flags and the decimal temperature (in the last 4 bits). Therefore, only the last 4 bits should be considered to extract the temperature in Celsius.

Without this fix, when the sensor is within the alert range the flags cause the temperature to interpreted incorrectly.
Diogo F. Andrade Murteira 1 年之前
父节点
当前提交
e591eaee45
共有 1 个文件被更改,包括 1 次插入1 次删除
  1. 1 1
      switchbot/__init__.py

+ 1 - 1
switchbot/__init__.py

@@ -86,7 +86,7 @@ def _process_wosensorth(data: bytes) -> dict[str, object]:
     """Process woSensorTH/Temp sensor services data."""
 
     _temp_sign = 1 if data[4] & 0b10000000 else -1
-    _temp_c = _temp_sign * ((data[4] & 0b01111111) + (data[3] / 10))
+    _temp_c = _temp_sign * ((data[4] & 0b01111111) + ((data[3] & 0b00001111) / 10))
     _temp_f = (_temp_c * 9 / 5) + 32
     _temp_f = (_temp_f * 10) / 10