@@ -6,9 +6,16 @@ import pytest
|
|
|
from bleak.backends.device import BLEDevice
|
|
from bleak.backends.device import BLEDevice
|
|
|
|
|
|
|
|
from switchbot import (
|
|
from switchbot import (
|
|
|
|
|
+ MeterProAlarmMode,
|
|
|
|
|
+ MeterProAlarmVolume,
|
|
|
|
|
+ MeterProCO2AlarmMode,
|
|
|
|
|
+ MeterProCO2AlarmStatus,
|
|
|
|
|
+ MeterProComfortStatus,
|
|
|
MeterProDateFormat,
|
|
MeterProDateFormat,
|
|
|
MeterProDisplaySource,
|
|
MeterProDisplaySource,
|
|
|
MeterProDisplayZone,
|
|
MeterProDisplayZone,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus,
|
|
|
MeterProZoneIcon,
|
|
MeterProZoneIcon,
|
|
|
SwitchbotOperationError,
|
|
SwitchbotOperationError,
|
|
|
)
|
|
)
|
|
@@ -478,3 +485,512 @@ async def test_co2_variant_shares_display_settings(
|
|
|
await getattr(device, method)(*args)
|
|
await getattr(device, method)(*args)
|
|
|
|
|
|
|
|
device._send_command.assert_called_with(expected_payload)
|
|
device._send_command.assert_called_with(expected_payload)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("device_class", "response", "expected"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (
|
|
|
|
|
+ SwitchbotMeterPro,
|
|
|
|
|
+ "01009c4600921e00",
|
|
|
|
|
+ {
|
|
|
|
|
+ "custom": False,
|
|
|
|
|
+ "temperature_low_c": 18.0,
|
|
|
|
|
+ "temperature_high_c": 28.0,
|
|
|
|
|
+ "humidity_low": 30,
|
|
|
|
|
+ "humidity_high": 70,
|
|
|
|
|
+ "status": MeterProComfortStatus.COMFORTABLE,
|
|
|
|
|
+ },
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ SwitchbotMeterProCO2,
|
|
|
|
|
+ "010180e3730080fe",
|
|
|
|
|
+ {
|
|
|
|
|
+ "custom": True,
|
|
|
|
|
+ "temperature_low_c": -0.3,
|
|
|
|
|
+ "temperature_high_c": 0.7,
|
|
|
|
|
+ "humidity_low": 0,
|
|
|
|
|
+ "humidity_high": 99,
|
|
|
|
|
+ "status": MeterProComfortStatus.WET,
|
|
|
|
|
+ },
|
|
|
|
|
+ ),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_get_comfort_level(
|
|
|
|
|
+ device_class: type[SwitchbotMeterPro],
|
|
|
|
|
+ response: str,
|
|
|
|
|
+ expected: dict[str, float | int | bool | MeterProComfortStatus],
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device(device_class)
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ assert await device.get_comfort_level() == expected
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f69020101")
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("limits", "custom", "expected"),
|
|
|
|
|
+ [
|
|
|
|
|
+ ((0.5, 22.34, 40, 82), True, "889652358028"),
|
|
|
|
|
+ ((-0.5, 0.66, 0, 99), True, "888063750000"),
|
|
|
|
|
+ ((18.0, 28.0, 30, 70), False, "809c4600921e"),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_comfort_level(
|
|
|
|
|
+ limits: tuple[float, float, int, int], custom: bool, expected: str
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+
|
|
|
|
|
+ await device.set_comfort_level(*limits, custom=custom)
|
|
|
|
|
+
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f680201" + expected)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("limits", "custom", "message"),
|
|
|
|
|
+ [
|
|
|
|
|
+ ((-128, 28.0, 30, 70), True, "Temperature must be"),
|
|
|
|
|
+ ((True, 28.0, 30, 70), True, "Temperature must be"),
|
|
|
|
|
+ ((18.01, 18.04, 30, 70), True, "Lower comfort limits"),
|
|
|
|
|
+ ((18, 28, 30, 100), True, "Humidity limits"),
|
|
|
|
|
+ ((18, 28, True, 70), True, "Humidity limits"),
|
|
|
|
|
+ ((18, 28, 70, 70), True, "Lower comfort limits"),
|
|
|
|
|
+ ((18, 28, 30, 70), 1, "custom must be a boolean"),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_comfort_level_rejects_invalid_input(
|
|
|
|
|
+ limits: tuple[float, float, int, int], custom: bool, message: str
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match=message):
|
|
|
|
|
+ await device.set_comfort_level(*limits, custom=custom)
|
|
|
|
|
+ device._send_command.assert_not_awaited()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ "response", ["02", "01", "01029c4600921e00", "01009c460a921e00", "01009c6400921e00"]
|
|
|
|
|
+)
|
|
|
|
|
+async def test_get_comfort_level_rejects_invalid_response(response: str):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError):
|
|
|
|
|
+ await device.get_comfort_level()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+async def test_set_comfort_level_rejects_device_error():
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ device._send_command.return_value = b"\x02"
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match="set_comfort_level"):
|
|
|
|
|
+ await device.set_comfort_level(18, 28, 30, 70)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("device_class", "response", "mode", "volume"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (SwitchbotMeterPro, "010000", MeterProAlarmMode.DISABLED, None),
|
|
|
|
|
+ (
|
|
|
|
|
+ SwitchbotMeterProCO2,
|
|
|
|
|
+ "010402",
|
|
|
|
|
+ MeterProAlarmMode.SOUND_AND_FLASH,
|
|
|
|
|
+ MeterProAlarmVolume.HIGH,
|
|
|
|
|
+ ),
|
|
|
|
|
+ (SwitchbotMeterPro, "01ff01", MeterProAlarmMode.FLASH_ONLY, None),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_get_alarm_settings(
|
|
|
|
|
+ device_class: type[SwitchbotMeterPro],
|
|
|
|
|
+ response: str,
|
|
|
|
|
+ mode: MeterProAlarmMode,
|
|
|
|
|
+ volume: MeterProAlarmVolume | None,
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device(device_class)
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ assert await device.get_alarm_settings() == {"mode": mode, "volume": volume}
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f690204")
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("mode", "volume", "payload"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (MeterProAlarmMode.DISABLED, None, "ff00"),
|
|
|
|
|
+ (MeterProAlarmMode.FLASH_ONLY, MeterProAlarmVolume.OFF, "0101"),
|
|
|
|
|
+ (MeterProAlarmMode.SOUND_AND_FLASH, MeterProAlarmVolume.LOW, "0202"),
|
|
|
|
|
+ (MeterProAlarmMode.SOUND_AND_FLASH, MeterProAlarmVolume.MEDIUM, "0302"),
|
|
|
|
|
+ (MeterProAlarmMode.SOUND_AND_FLASH, MeterProAlarmVolume.HIGH, "0402"),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_alarm_settings(
|
|
|
|
|
+ mode: MeterProAlarmMode, volume: MeterProAlarmVolume | None, payload: str
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+
|
|
|
|
|
+ await device.set_alarm_settings(mode, volume)
|
|
|
|
|
+
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f680204" + payload)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize("response", ["02", "0100", "010403"])
|
|
|
|
|
+async def test_get_alarm_settings_rejects_invalid_response(response: str):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError):
|
|
|
|
|
+ await device.get_alarm_settings()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("mode", "volume", "message"),
|
|
|
|
|
+ [(True, None, "mode must be"), (MeterProAlarmMode.DISABLED, 5, "volume must be")],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_alarm_settings_rejects_invalid_input(
|
|
|
|
|
+ mode: object, volume: object, message: str
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match=message):
|
|
|
|
|
+ await device.set_alarm_settings(mode, volume)
|
|
|
|
|
+
|
|
|
|
|
+ device._send_command.assert_not_awaited()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+async def test_set_alarm_settings_rejects_device_error():
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ device._send_command.return_value = b"\x02"
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match="set_alarm_settings"):
|
|
|
|
|
+ await device.set_alarm_settings(MeterProAlarmMode.DISABLED)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("response", "mode", "status"),
|
|
|
|
|
+ [
|
|
|
|
|
+ ("01000578019000", MeterProCO2AlarmMode.DISABLED, MeterProCO2AlarmStatus.NONE),
|
|
|
|
|
+ (
|
|
|
|
|
+ "010b05780190fe",
|
|
|
|
|
+ MeterProCO2AlarmMode.CUSTOM
|
|
|
|
|
+ | MeterProCO2AlarmMode.LOW
|
|
|
|
|
+ | MeterProCO2AlarmMode.HIGH,
|
|
|
|
|
+ MeterProCO2AlarmStatus.HIGH,
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ "01840578019003",
|
|
|
|
|
+ MeterProCO2AlarmMode(0x84),
|
|
|
|
|
+ MeterProCO2AlarmStatus.IN_RANGE,
|
|
|
|
|
+ ),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_get_co2_alarm(
|
|
|
|
|
+ response: str, mode: MeterProCO2AlarmMode, status: MeterProCO2AlarmStatus
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device(SwitchbotMeterProCO2)
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ assert await device.get_co2_alarm() == {
|
|
|
|
|
+ "mode": mode,
|
|
|
|
|
+ "low_ppm": 400,
|
|
|
|
|
+ "high_ppm": 1400,
|
|
|
|
|
+ "status": status,
|
|
|
|
|
+ }
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f69020301")
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("mode", "low", "high", "payload"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (MeterProCO2AlarmMode.DISABLED, 400, 1400, "0005780190"),
|
|
|
|
|
+ (MeterProCO2AlarmMode.LOW, 401, 1101, "01044d0191"),
|
|
|
|
|
+ (MeterProCO2AlarmMode.HIGH, 0, 0xFFFF, "02ffff0000"),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProCO2AlarmMode.LOW | MeterProCO2AlarmMode.HIGH,
|
|
|
|
|
+ 425,
|
|
|
|
|
+ 2000,
|
|
|
|
|
+ "0307d001a9",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (MeterProCO2AlarmMode.IN_RANGE, 1200, 1200, "0404b004b0"),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProCO2AlarmMode.HIGH | MeterProCO2AlarmMode.CUSTOM,
|
|
|
|
|
+ 425,
|
|
|
|
|
+ 2000,
|
|
|
|
|
+ "0a07d001a9",
|
|
|
|
|
+ ),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_co2_alarm(
|
|
|
|
|
+ mode: MeterProCO2AlarmMode, low: int, high: int, payload: str
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device(SwitchbotMeterProCO2)
|
|
|
|
|
+
|
|
|
|
|
+ await device.set_co2_alarm(mode, low, high)
|
|
|
|
|
+
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f68020301" + payload)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize("response", ["02", "010005780190"])
|
|
|
|
|
+async def test_get_co2_alarm_rejects_invalid_response(response: str):
|
|
|
|
|
+ device = create_device(SwitchbotMeterProCO2)
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match="get_co2_alarm"):
|
|
|
|
|
+ await device.get_co2_alarm()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("mode", "low", "high", "message"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (True, 400, 1400, "Invalid CO2 alarm mode"),
|
|
|
|
|
+ (MeterProCO2AlarmMode(0x10), 400, 1400, "Invalid CO2 alarm mode"),
|
|
|
|
|
+ (MeterProCO2AlarmMode.LOW, True, 1400, "unsigned 16-bit integers"),
|
|
|
|
|
+ (MeterProCO2AlarmMode.LOW, -1, 1400, "unsigned 16-bit integers"),
|
|
|
|
|
+ (MeterProCO2AlarmMode.LOW, 400, 0x10000, "unsigned 16-bit integers"),
|
|
|
|
|
+ (MeterProCO2AlarmMode.LOW, 400, 1400.0, "unsigned 16-bit integers"),
|
|
|
|
|
+ (MeterProCO2AlarmMode.IN_RANGE, 1400, 400, "Lower CO2 alarm limit"),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_co2_alarm_rejects_invalid_input(
|
|
|
|
|
+ mode: object, low: object, high: object, message: str
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device(SwitchbotMeterProCO2)
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match=message):
|
|
|
|
|
+ await device.set_co2_alarm(mode, low, high)
|
|
|
|
|
+
|
|
|
|
|
+ device._send_command.assert_not_awaited()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+async def test_set_co2_alarm_rejects_device_error():
|
|
|
|
|
+ device = create_device(SwitchbotMeterProCO2)
|
|
|
|
|
+ device._send_command.return_value = b"\x02"
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match="set_co2_alarm"):
|
|
|
|
|
+ await device.set_co2_alarm(MeterProCO2AlarmMode.DISABLED, 400, 1400)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+def test_co2_alarm_is_only_available_on_the_co2_model():
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+
|
|
|
|
|
+ assert not hasattr(device, "get_co2_alarm")
|
|
|
|
|
+ assert not hasattr(device, "set_co2_alarm")
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("device_class", "response", "expected"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (
|
|
|
|
|
+ SwitchbotMeterPro,
|
|
|
|
|
+ "0100000000000000",
|
|
|
|
|
+ {
|
|
|
|
|
+ "mode": MeterProTemperatureHumidityAlarmMode.DISABLED,
|
|
|
|
|
+ "temperature_low_c": 0.0,
|
|
|
|
|
+ "temperature_high_c": 0.0,
|
|
|
|
|
+ "humidity_low": 0,
|
|
|
|
|
+ "humidity_high": 0,
|
|
|
|
|
+ "temperature_status": MeterProTemperatureHumidityAlarmStatus.NONE,
|
|
|
|
|
+ "humidity_status": MeterProTemperatureHumidityAlarmStatus.NONE,
|
|
|
|
|
+ },
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ SwitchbotMeterProCO2,
|
|
|
|
|
+ "014297a745009423",
|
|
|
|
|
+ {
|
|
|
|
|
+ "mode": (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.TEMPERATURE_HIGH
|
|
|
|
|
+ | MeterProTemperatureHumidityAlarmMode.HUMIDITY_IN_RANGE
|
|
|
|
|
+ ),
|
|
|
|
|
+ "temperature_low_c": -0.5,
|
|
|
|
|
+ "temperature_high_c": 23.4,
|
|
|
|
|
+ "humidity_low": 20,
|
|
|
|
|
+ "humidity_high": 39,
|
|
|
|
|
+ "temperature_status": MeterProTemperatureHumidityAlarmStatus.HIGH,
|
|
|
|
|
+ "humidity_status": MeterProTemperatureHumidityAlarmStatus.IN_RANGE,
|
|
|
|
|
+ },
|
|
|
|
|
+ ),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_get_temperature_humidity_alarm(
|
|
|
|
|
+ device_class: type[SwitchbotMeterPro], response: str, expected: dict[str, object]
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device(device_class)
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ assert await device.get_temperature_humidity_alarm() == expected
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f69020100")
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("response", "temperature_status", "humidity_status"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (
|
|
|
|
|
+ "0122963695000a20",
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.HIGH,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.NONE,
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ "0122a32795000a02",
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.NONE,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.HIGH,
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ "0122972735001822",
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.HIGH,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.HIGH,
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ "0122963695000aec",
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.HIGH,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.NONE,
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ "0122a32795000ace",
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.NONE,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.HIGH,
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ "014297a7450094ff",
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.IN_RANGE,
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmStatus.IN_RANGE,
|
|
|
|
|
+ ),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_get_temperature_humidity_alarm_status(
|
|
|
|
|
+ response: str,
|
|
|
|
|
+ temperature_status: MeterProTemperatureHumidityAlarmStatus,
|
|
|
|
|
+ humidity_status: MeterProTemperatureHumidityAlarmStatus,
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ result = await device.get_temperature_humidity_alarm()
|
|
|
|
|
+
|
|
|
|
|
+ assert result["temperature_status"] is temperature_status
|
|
|
|
|
+ assert result["humidity_status"] is humidity_status
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("mode", "limits", "payload"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (MeterProTemperatureHumidityAlarmMode.DISABLED, (0, 0, 0, 0), "008000008000"),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.TEMPERATURE_HIGH
|
|
|
|
|
+ | MeterProTemperatureHumidityAlarmMode.HUMIDITY_HIGH,
|
|
|
|
|
+ (-0.5, 23.34, 20, 39),
|
|
|
|
|
+ "229727350014",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.TEMPERATURE_IN_RANGE
|
|
|
|
|
+ | MeterProTemperatureHumidityAlarmMode.HUMIDITY_IN_RANGE,
|
|
|
|
|
+ (0.5, 0.5, 0, 99),
|
|
|
|
|
+ "448063558000",
|
|
|
|
|
+ ),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_temperature_humidity_alarm(
|
|
|
|
|
+ mode: MeterProTemperatureHumidityAlarmMode,
|
|
|
|
|
+ limits: tuple[float, float, int, int],
|
|
|
|
|
+ payload: str,
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+
|
|
|
|
|
+ await device.set_temperature_humidity_alarm(mode, *limits)
|
|
|
|
|
+
|
|
|
|
|
+ device._send_command.assert_awaited_once_with("570f680201" + payload)
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ ("mode", "limits", "message"),
|
|
|
|
|
+ [
|
|
|
|
|
+ (True, (18, 28, 30, 70), "Invalid temperature and humidity alarm mode"),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode(0x88),
|
|
|
|
|
+ (18, 28, 30, 70),
|
|
|
|
|
+ "Invalid temperature and humidity alarm mode",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode(0x08),
|
|
|
|
|
+ (18, 28, 30, 70),
|
|
|
|
|
+ "Invalid temperature and humidity alarm mode",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.DISABLED,
|
|
|
|
|
+ (-128, 28, 30, 70),
|
|
|
|
|
+ "Temperature must be",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.DISABLED,
|
|
|
|
|
+ (18, 28, True, 70),
|
|
|
|
|
+ "Humidity limits",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.DISABLED,
|
|
|
|
|
+ (18, 28, 30, 100),
|
|
|
|
|
+ "Humidity limits",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.TEMPERATURE_IN_RANGE,
|
|
|
|
|
+ (28, 18, 30, 70),
|
|
|
|
|
+ "Lower in-range alarm limits",
|
|
|
|
|
+ ),
|
|
|
|
|
+ (
|
|
|
|
|
+ MeterProTemperatureHumidityAlarmMode.HUMIDITY_IN_RANGE,
|
|
|
|
|
+ (18, 28, 70, 30),
|
|
|
|
|
+ "Lower in-range alarm limits",
|
|
|
|
|
+ ),
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_set_temperature_humidity_alarm_rejects_invalid_inputs(
|
|
|
|
|
+ mode: object, limits: tuple[float, float, int, int], message: str
|
|
|
|
|
+):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match=message):
|
|
|
|
|
+ await device.set_temperature_humidity_alarm(mode, *limits)
|
|
|
|
|
+
|
|
|
|
|
+ device._send_command.assert_not_awaited()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+@pytest.mark.parametrize(
|
|
|
|
|
+ "response",
|
|
|
|
|
+ [
|
|
|
|
|
+ "02",
|
|
|
|
|
+ "01000000000000",
|
|
|
|
|
+ "01009c460a921e00",
|
|
|
|
|
+ "01009c6400921e00",
|
|
|
|
|
+ ],
|
|
|
|
|
+)
|
|
|
|
|
+async def test_get_temperature_humidity_alarm_rejects_invalid_response(response: str):
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ device._send_command.return_value = bytes.fromhex(response)
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError):
|
|
|
|
|
+ await device.get_temperature_humidity_alarm()
|
|
|
|
|
+
|
|
|
|
|
+
|
|
|
|
|
+@pytest.mark.asyncio
|
|
|
|
|
+async def test_set_temperature_humidity_alarm_rejects_device_error():
|
|
|
|
|
+ device = create_device()
|
|
|
|
|
+ device._send_command.return_value = b"\x02"
|
|
|
|
|
+
|
|
|
|
|
+ with pytest.raises(SwitchbotOperationError, match="set_temperature_humidity_alarm"):
|
|
|
|
|
+ await device.set_temperature_humidity_alarm(
|
|
|
|
|