@@ -4,14 +4,18 @@ import pytest
|
|
|
from bleak.backends.device import BLEDevice
|
|
|
|
|
|
from switchbot import SwitchbotOperationError
|
|
|
-from switchbot.devices.meter_pro import MAX_TIME_OFFSET, SwitchbotMeterProCO2
|
|
|
+from switchbot.devices.meter_pro import (
|
|
|
+ MAX_TIME_OFFSET,
|
|
|
+ SwitchbotMeterPro,
|
|
|
+ SwitchbotMeterProCO2,
|
|
|
+)
|
|
|
|
|
|
|
|
|
-def create_device():
|
|
|
+def create_device(cls=SwitchbotMeterProCO2):
|
|
|
ble_device = BLEDevice(
|
|
|
address="aa:bb:cc:dd:ee:ff", name="any", details={"rssi": -80}
|
|
|
)
|
|
|
- device = SwitchbotMeterProCO2(ble_device)
|
|
|
+ device = cls(ble_device)
|
|
|
device._send_command = AsyncMock()
|
|
|
return device
|
|
|
|
|
|
@@ -248,3 +252,20 @@ async def test_set_time_display_format_failure():
|
|
|
|
|
|
with pytest.raises(SwitchbotOperationError):
|
|
|
await device.set_time_display_format(is_12h_mode=True)
|
|
|
+
|
|
|
+
|
|
|
+@pytest.mark.asyncio
|
|
|
+async def test_meter_pro_shares_datetime_protocol_with_co2_variant():
|
|
|
+ """The plain Meter Pro (no CO2 sensor) uses the same BLE commands as the CO2 variant."""
|
|
|
+ device = create_device(SwitchbotMeterPro)
|
|
|
+ device._send_command.return_value = bytes.fromhex("01e40294230007e90c1e083701")
|
|
|
+
|
|
|
+ result = await device.get_datetime()
|
|
|
+ device._send_command.assert_called_with("570f6901")
|
|
|
+ assert result["year"] == 2025
|
|
|
+
|
|
|
+ device._send_command.return_value = bytes.fromhex("01")
|
|
|
+ await device.set_datetime(1709251200)
|
|
|
+ device._send_command.assert_called_with(
|
|
|
+ "57000503" + "0c" + "65e11a80".zfill(16) + "00"
|
|
|
+ )
|